Another oil furnace question

Discussion in 'The Garage' started by AlanCT, Jan 19, 2013.

  1. AlanCT

    AlanCT The Byronic Man

    Joined:
    Apr 15, 2009
    Oddometer:
    3,836
    Location:
    Northeastern CT
    Hi,

    So apparently when we had our furnace serviced a month ago, the repair man left the fuel petcock for one of our two oil tanks in the off position. As a result, the furnace ran dry after using the oil up in one tank. Normally, it draws from both tanks at once.

    Today, I got an oil delivery, bled the air out of the line and now the furnace is up and running.

    However, the oil delivery we got filled one tank, but didn't cross over to the other. Normally the two tanks balance when filled, because they have a common fill pipe, and the furnace draws oil from both. What's the deal? How come the oil isn't balancing between the two tanks? How do I get it back to normal?

    I dont know if it was necessary, but I shut the petcock off for the empty one so it doesn't suck more air.
    #1
  2. AlanCT

    AlanCT The Byronic Man

    Joined:
    Apr 15, 2009
    Oddometer:
    3,836
    Location:
    Northeastern CT
    Okay, it seems like they are starting to equalize, just very, very slowly.
    #2
  3. concours

    concours WFO for 41 years

    Joined:
    Dec 2, 2008
    Oddometer:
    5,454
    Location:
    Kensington, NH USA
    Observed that same thing at my buddies house, I was checking on it for him while he was away all winter on vaca. Didn't equalize, then finally did. This is a GREAT reason to follow accepted service procedure and BLOW OUT THE LINES periodically. I'm guilty of not doing it enough... S L U D G E
    #3
  4. rapidoxidationman

    rapidoxidationman Easily trainable

    Joined:
    Apr 18, 2006
    Oddometer:
    9,195
    Location:
    The Teton Rockies
    I wonder if a half barrel of bio diesel would clean things up... Just make sure you have a couple of new fuel filters on hand.
    #4
  5. DC2wheels

    DC2wheels Castle Anthrax troll

    Joined:
    Jul 11, 2008
    Oddometer:
    2,851
    Location:
    N.H.
    I run the furnace at my office on kerosene.

    Pricey? Sure. But my tank is outside- so no winter problems. And the furnace, tank and lines stay CLEAN.

    More $$ but cheaper long term? Maybe. Plus less worries.
    #5
  6. concours

    concours WFO for 41 years

    Joined:
    Dec 2, 2008
    Oddometer:
    5,454
    Location:
    Kensington, NH USA
    It's real easy... turn off emergency switch, disconnect both ends of the fuel line, stick one end in a gallon jug, blast it from the other end with compressed air, reconnect line, connect catch hose and open bleeder, turn on switch run till clear fuel, close bleeder. Repeat every two years.
    #6
  7. HapHazard

    HapHazard Waiting for Gudenov

    Joined:
    Dec 30, 2009
    Oddometer:
    2,388
    Location:
    Central CT
    How much is K1 in NH? I have a Monitor 30 in my garage, and it's getting hard to find K1 in CT. I paid $5 a gallon at a fuel dealer, which beats the $10 a gallon at Home Despot.:eek1
    #7
  8. DC2wheels

    DC2wheels Castle Anthrax troll

    Joined:
    Jul 11, 2008
    Oddometer:
    2,851
    Location:
    N.H.
    We are just over $4/gallon.
    #8
  9. Lorretto

    Lorretto City Dweller Crushperado

    Joined:
    Feb 18, 2005
    Oddometer:
    349
    Location:
    Washington, DC
    A lifetime ago I delivered #2 heating oil. If the tanks aren't equalizing you usually have a vent problem. With a common fill, there should be two vents. If the second tank isn't venting or venting really slow, the delivery driver is hearing the first vent close and shuts down the pump thinking they [both tanks] are full. As mentioned, sludge can be a problem but since the tanks feed the system to empty it could cause the slow equalization but not the false full.


    First your oil delivery company will probably check the vents for free as they want to sell you oil and it is easier for them to drop 500 gallons twice a season than 250 four times.


    Generally next to the fill pipe are the vent lines. Pull the covers and see if critters have taken up residence in the vent, if so, clear and you're done.
    #9
  10. spafxer

    spafxer Long timer

    Joined:
    Mar 12, 2007
    Oddometer:
    2,668
    Being that I'm from California and have only heated with natural gas...............


    AND, being this is ADV and all...................................................................


    I'm going to take a wild guess...................................................................





    YOUR FURNACE IS TELLING YOU IT'S TIME TO CHANGE TO SYNTHETIC FURNACE OIL!!!!!











    :jump:hide
    #10
  11. ttpete

    ttpete Rectum Non Bustibus

    Joined:
    May 13, 2009
    Oddometer:
    6,250
    Location:
    Dearborn, MI
    Why does the East coast heat with oil? We've had natural gas here for 60 years or better. Are there no pipelines in New England?
    #11
  12. concours

    concours WFO for 41 years

    Joined:
    Dec 2, 2008
    Oddometer:
    5,454
    Location:
    Kensington, NH USA
    The road I live on is 350 years old, nothing but rock and clay down there. We have natural gas in the cities... but rural areas not so much.
    #12
  13. concours

    concours WFO for 41 years

    Joined:
    Dec 2, 2008
    Oddometer:
    5,454
    Location:
    Kensington, NH USA
    LOL and at $12 a QUART, I'll sleep better knowing the $100 Sundstrand pump will last 300,000 miles!
    #13
  14. TeneRay

    TeneRay 2>4

    Joined:
    Aug 16, 2009
    Oddometer:
    2,256
    Location:
    2-D, OH and SoVA
    I don't understand how people here still have oil burning furnaces, either. I'm in this shitty rental for another week but have refused to fill up the 300 gallon tank with $4/gal kerosene (yeah, gasoline drops but not kero).

    I tried earlier in the season just to see what the rate of consumption was. Yeah, I went through 10 gallons in 3 days keeping the house at 70F. Since then, I just purchased one of those small convection burners and seek shelter in the bedroom. It's 20ish outside and about 45 in the rest of the house.

    Seriously, two seasons of filling up that tank will literally pay for a new heat pump system and pay itself off in no time.
    #14
  15. 1greenmachine

    1greenmachine Been here awhile

    Joined:
    Aug 28, 2010
    Oddometer:
    856
    Location:
    green bay, wi
    I was talking with a HVAC guy and the waste oil subject came up and its mainly the old people that insist on fixing that old ineffient oil burner and forget trying to sell them a newer propane unit. I've got a 1699 sgft ranch that cost me 160 to heat last month and would hate to pay for waste oil
    #15
  16. KeithinSC

    KeithinSC Long timer

    Joined:
    Oct 18, 2009
    Oddometer:
    1,758
    Location:
    Sandhills of SC
    Probably too cold 3-4 months of a year for a heat pump to work in N.E.
    #16
  17. ttpete

    ttpete Rectum Non Bustibus

    Joined:
    May 13, 2009
    Oddometer:
    6,250
    Location:
    Dearborn, MI
    Not so. I installed one in my family room to replace a wall mount gas heater and an air conditioner, and saved almost $750 the first year. The unit sits outside and is plumbed to an air handler on the back wall. It's 18,000 BTU and is made in Germany. Brand name is Grunaire.
    #17
  18. small_e_900

    small_e_900 Amanda carried it

    Joined:
    Aug 21, 2007
    Oddometer:
    1,848
    Location:
    Mudpuddle Maine
    I would switch to natural gas in a second.
    The nearest gas lines are 10 miles away
    Gas heat, hot water. clothes dryer and cooking and only one bill.

    Propane would cost as much or possibly more than oil.
    #18
  19. _cy_

    _cy_ Long timer

    Joined:
    Sep 25, 2011
    Oddometer:
    6,468
    Location:
    Tulsa, Oklahoma
    switch to wood heat ... have been on wood heat for 6 seasons. it's the only place that you've got control of your utility costs.

    saves me $350+ per month in heating bills ... wood is free but the labor to harvest is not. yes it's a bit of work, but well worth it!!!
    #19
  20. rapidoxidationman

    rapidoxidationman Easily trainable

    Joined:
    Apr 18, 2006
    Oddometer:
    9,195
    Location:
    The Teton Rockies
    How cold does it get there?

    18,000 BTU is about 1/5th the size needed here...
    #20